European magazine for pools, spas and wellness
Pool and spa business magazine
SPA POOL NEWS

Bubbles from pool jets and a pump sucking air: finding the leak

Practical steps for bubbles from the jets, an airlocked pump, lost prime, suction leaks, the skimmer, pump lid, O-ring, valves and filtration.

Spa Pool News featured image
Bubbles from pool jets and a pump sucking air: finding the leak - Spa Pool News

Quick answer: bubbles from the return jets usually mean air is entering the system before the pump. Start with the water level and skimmer, then check the pump basket, lid, O-ring, drain plugs, valves and suction lines. If the pump will not prime or keeps running with air in it, do not let it run dry for long.

A leak on the suction side is tricky because water does not necessarily leak out visibly. The system is under negative pressure there, so instead of dripping you will often see bubbles in the pump and jets. Sometimes, though, bubbles are a normal part of ozone, AOP or air injection systems. That is why you need to work out when the bubbles started and what mode the equipment is running in.

Checklist for bubbles and air in the system

Area Question Risk What to do
Water level is the water level high enough that the skimmer is not drawing in air? a low water level or a vortex in the skimmer lets air into the pump and sends bubbles to the jets top up the water, and check the skimmer weir, basket and for a vortex while the pump is running
Pump basket is the pump’s clear lid full of water, or is there a large air pocket inside? a pump running dry or with air in it loses performance and can be damaged switch off the pump, clean the basket, fill the chamber with water, and re-prime it according to the manufacturer’s instructions
Lid and O-ring is the pump lid clean, properly tightened, and is the O-ring undamaged? a small leak at the lid often lets air in while barely any water leaks out clean the sealing surfaces, check the O-ring, apply a suitable lubricant as specified by the manufacturer, and seat the lid correctly
Suction pipework and valves do bubbles appear after switching suction between the skimmer, the main drain or the vacuum port? a leaking valve, joint, hose or vacuum fitting may draw in air only in a particular mode test each line one at a time, watch how the bubbles change, and note the problem line for the service technician
Drain plugs are the pump and filter drain plugs, or the winterizing plugs, properly tightened and sealed? a small leak left after winterizing or a service visit will draw air into the system switch off the equipment, and check the plugs, seals and threads as directed
Filter and pressure has the filter pressure risen, is flow weak, or does the pump sound different? a clogged filter, a closed valve or resistance in the system can worsen flow and priming clean or backwash the filter, open the correct valves, and compare the pressure with its normal level
Equipment that makes bubbles do you have ozone, AOP, an air blower, a water feature or hot tub jets? some systems create bubbles on purpose, so this is not necessarily a suction fault switch off the add-on equipment and check whether the bubbles disappear; distinguish normal operation from a new problem
When to call a service technician does the pump still not prime, do the bubbles keep coming back, or is pressure still low after a basic check? this can point to a cracked pipe, a leaking valve, a damaged pump, worn seals or an installation fault prepare photos of the pump, the lid and the skimmer, the filter pressure, the valve positions, and a note of when the bubbles started

Safe procedure

  1. Check the water level and the skimmer. The level must be high enough, and the skimmer must not be forming a vortex.
  2. Switch off the pump, open the pump basket as directed, clean the basket, and check the lid.
  3. Inspect the lid’s O-ring, the sealing surfaces, the plugs and the seals.
  4. Fill the pump chamber with water and prime the pump according to the manufacturer’s instructions.
  5. Start the pump and watch whether the chamber fills with water and the bubbles disappear.
  6. Test the suction lines one at a time: the skimmer, the main drain, the vacuum port, and any other circuits.
  7. Clean the filter and compare the pressure and flow with their normal level.
  8. If the pump keeps losing its prime, prepare the information for a service technician and do not keep running it dry for long.

Common mistakes

  • Trying to fix bubbles in the jets with chemicals when the cause is mechanical.
  • Letting the pump run for a long time when it is not primed.
  • Overlooking a low water level or a stuck skimmer weir.
  • Tightening the lid over a dirty O-ring or a damaged seal.
  • Not rinsing or backwashing the filter, or not checking the pressure.
  • Mistaking normal bubbles from ozone or air injection for a suction leak.

Where to go next

Sources and background

This is based on installation and service guidance from pool pump manufacturers covering priming, the pump lid, O-rings, suction leaks and filtration. For your specific pump, filter, valve and wiring, always follow the manufacturer’s instructions first, and only work on the equipment once it is safely switched off.